  series ames15-maz 15 watt | ac-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r7.l 1 of 5 north america only features: ? screw terminals on input & output ? rohs compliant ? operating temperature: -40 to +80c ? soft start ? over load, over voltage, short circuit protection ? energy star compliant ? optional din rail mounting bracket ? ce, culus, cb approvals ? universal input: 90-264vac, 47-440hz ? 4000vac i/o isolation models single output model input voltage (vac/hz) input voltage (vdc) max output wattage (w) output voltage (v) output current max (a) ripple & noise (mv) maximum capacitive load (f) efficiency (%) ames15-3.3smaz 90-264/47-440 120-370 9.9 3.3 3 50 4700 74 ames15-5smaz 90-264/47-440 120-370 15 5 3 50 2200 78 ames15-12smaz 90-264/47-440 120-370 15 12 1.25 100 1000 81 ames15-15smaz 90-264/47-440 120-370 15 15 1 100 680 81 ames15-24smaz 90-264/47-440 120-370 15 24 0.63 100 470 83 models dual output model input voltage (vac/hz) input voltage (vdc) max output wattage (w) output voltage (v) output current max (a) ripple & noise * (mv) maximum capacitive load (f) efficiency (%) ames15-5dmaz 90-264/47-440 120-370 15 5 1.5 50 1000 78 ames15-12dmaz 90-264/47-440 120-370 15 12 0.63 100 470 80 ames15-15dmaz 90-264/47-440 120-370 15 15 0.5 100 330 81 * ripple & noise measured with 1f m/c and 47f e/c (20mhz bandwidth) input specifications parameters conditions typical maximum units current 115vac 350 ma 230vac 180 ma inrush current <2ms 115 vac 10 a 230 vac 20 a leakage current 115 vac 0.1 ma 264 vac 0.2 ma external fuse (recommend) slow blow type 2 a input dissipation no load <0.5 w under voltage protection 88 vac output specifications parameters conditions typical maximum units voltage accuracy 2 % line regulation ll-hl 0.5 % load regulation (single output) 0-100% 0.5 % cross regulation (dual output) 25% load - 1 s t out, 100% load ? 2 n d out 5 % transient recovery time 200 s transient recovery deviation 25% load step 2 % of vout hold-up time min 20 ms cb
series ames15-maz 15 watt | ac-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r7.l 2 of 5 north america only isolation specifications parameters conditions typical rated units tested i/o voltage 3 sec 4000 vac isolation resistance >1000 m ? general specifications parameters conditions typical maximum units switching frequency 132 khz start up time 900 ms over load protection auto recovery, hiccup mode >131 % over voltage protection zener diode clamp short circuit protection continuous short circuit restart auto recovery operating temperature with derating over 55 o c (10cfm) -40 to +80 o c storage temperature -50 to +100 o c max case temperature 100 o c temperature coefficient 0.02 % / o c cooling free air convection humidity 95 % rh weight 100 g dimensions (l x w x h) 3.62 x 2.56 x 0.94 inches 92.0 x 65.0 x 24.0 mm mtbf > 400 000hrs (mil-hdbk -217f, t=+25 o c) note: all specifications in this datasheet are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. environment approval parameters conditions shock wave form: half sine wave acceleration amplitude: 5gn bump duration: 30 ms number of bumps: 18 (3 in each direction for every axis) converter operation before and after test, body mounted (on chassis) vibrations test mode: sweep sine 10-100hz, speed 0.05hz/s displacement: 1mm acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested converter operation before and after test, body mounted (on chassis) safety & emc specifications parameters agency approvals culus, ce, cb standards medical electrical equipment iec\en\ul 60601-1 , csa-c22.2 no. 601.1-m90 information technology equipment en 60950-1:2006+a11:2009 emi - conducted and radiated emission en55011, class b harmonic current emissions iec/en 61000-3-2, (en60555-2) voltage fluctuations and flicker iec/en 61000-3-3, (en60555-3) electrostatic discharge immunity iec 61000-4-2 rf, electromagnetic field immunity iec 61000-4-3 electrical fast transient/burst immunity iec 61000-4-4 surge immunity iec 61000-4-5 rf, conducted disturbance immunity iec 61000-4-6 power frequency magnetic field immunity iec 61000-4-8 voltage dips, short interruptions immunity iec 61000-4-11
series ames15-maz 15 watt | ac-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r7.l 3 of 5 north america only derating - 40 - 20 0 20 40 60 80 100 ambient temperature o c 100 80 60 40 20 0 safe operating area 85 a b 40 o c a 10 cfm free air convection 55 o c b pin out specifications pin single dual 1 ac input (n) ac input (n) 2 ac input (l) ac input (l) 3 -v output -v output 4 no connection common 5 +v output +v output
series ames15-maz 15 watt | ac-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r7.l 4 of 5 north america only dimensions pcb bracket mountin g screw mylar film pcb mounting screw pcb mounting screw 2.6 mm max customer chassis pcb mylar film 24
series ames15-maz 15 watt | ac-dc converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052e r7.l 5 of 5 north america only optional din rail bracket note: 1. datasheets are updated as needed and as such, specifications ar e subject to change without notic e. once printed or downloaded , datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety a gency certifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an ambient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conduct ed destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are consi dered proprietary and may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear contr ol systems or other such applications which necessitate specific safety and regulatory st andards other the ones listed in this datasheet. 7. warranty is in accordance with aimtec ?s standard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AMES15-33SMAZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X